Quote Due Date: Quote Type: Firm Budget Personal Information Name E-mail Address Phone Number Fax Company Name Address Tank Location City State Country Labor Type -- Nonunion labor Union labor Prevailing wage nonunion By others Reference Project
Quantity - Carbon steel Stainless steel 304 Stainless steel 316 Materials Of Construction Construction Method - 9.23 12.31 15.38 18.46 21.54 24.62 27.69 29.71 32.68 35.65 38.62 41.59 44.56 47.53 50.51 53.48 56.45 59.42 62.39 65.36 68.33 71.30 74.27 77.24 80.21 83.19 86.16 89.17 92.10 95.07 98.04 101.01 103.98 106.95 109.92 112.98 115.87 118.84 121.81 Nominal Inside Diameter (ft.) Nominal Eave Height (ft.) Usable Capacity (gallons) - 12" 18" 24" 30" 36" 42" Freeboard (in.) - Flat bottom Embedded base setting ring Bottom Style Deck Slope - 2" rise to 12" run Aluminum dome Open top
Criteria - AWWA D103 (latest edition) NFPA-22 Tank Connection standard Design Specifications Seismic Design - 0 1 2A 2B 3 4 Seismic Zone Wind Design Wind Conditions Roof Live Load (lbs./sq. ft) Product Stored Specific Gravity Design Pressure (oz./sq. in.) Design Vacuum(oz./sq. in.) Operating Pressure(oz./sq. in.) Operating Vacuum(oz./sq. in.) Design Temperature Operating Temperature
Interior Coating 7ml Average DFT 7ml Average DFT Exterior Primer 3ml Average DFT Exterior Finish Coat 2ml Average DFT
Manway/Vents Qty: 20" diameter mushroom ventilator with bird screen Qty: 24" square roof manway with lockable hinged cover Qty: 24" 30" 36" Diameter Shell Manway with Bolt-on Hinged Cover Nozzles/Overflow Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle for inlet Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle for outlet Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle for drain Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle with internal 90° elbow and vortex breaker for suction Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter internal 90° weir elbow with external sch10 downcomer pipe and flap valve for overflow Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 150# RFSO single flanged nozzle Couplings Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 3000# half coupling Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 3000# half coupling Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 3000# full coupling Qty: 1/2" 3/4" 1" 1 1/4" 1 1/2" 2" 2 1/2" 3" 3 1/2" 4" 5" 6" 8" 10" 12" 14" 16" 18" 20" 24" 30" 36" diameter 3000# full coupling Ladders Outside ladder None Outside caged ladder with lockable hoop and rest platform (if required) — OSHA — HDG Outside un-caged straight-run ladder with SAF-T CLIMB, harness and sleeve — OSHA — HDG Inside ladder None Inside un-caged straight-run ladder — Painted Inside un-caged straight-run ladder with SAF-T-CLIMB, harness and sleeve — Painted Level Indicators Liquid level indicator with gauge board and high visibility target Liquid level indicator with gauge board and high visibility target High/low level indicator Miscellaneous Components/Services Immersion heater Insulation — Vertical standing seam system consisting of 2" thick polyisocyanurate foam board laminated to a painted aluminum exterior panel Foundation design (based on customer supplied soils report) Other Requirements